,for, Item ID-
- #1090986
- Ortho Clinical Diagnostics #MTS080017
Hematology Reagent MTS™ A / B Monoclonal Grouping CLIA Non-Waived For Ortho Vision / Ortho Vision Max / ID-MTS Workstation / Ortho ProVue Analyzers 100 Tests
MTS CARD, AB MONO GROUP (100/CS)
No Image
Features
- MTS™ Buffered Gel Card can be used in ABO Serum Grouping as well as direct agglutination i.e., cold and warm antibody detection
- Delivered with gel-filled microtubes infused with pre-measured reagents
- Gel testing is easy to learn, use, and teach: the ideal technology for all shifts and all levels of blood banking experience
- More …
Product Details Email
Product Specifications
McKesson # | 1090986 |
---|---|
Manufacturer # | MTS080017 |
Brand | MTS™ |
Manufacturer | Ortho Clinical Diagnostics |
Country of Origin | United States |
Application | Hematology Reagent |
CLIA Classification | CLIA Moderate Complexity for Routine Blood Typing (Information Only) / CLIA High Complexity for Compatibility Testing |
CLIA Classified | CLIA Non-Waived |
For Use With | For Ortho Vision / Ortho Vision Max / ID-MTS Workstation / Ortho ProVue Analyzers |
Form | Liquid |
Number of Tests | 100 Tests |
Product Dating | McKesson Acceptable Dating: we will ship >= 60 days |
Sample Type | Whole Blood / Serum / Plasma Sample |
Specialty | Hematology |
Test Category | Blood Bank |
Test Format | Gel Card |
Test Name | A / B Monoclonal Grouping |
Test Type | Blood Grouping Test |
UNSPSC Code | 41116101 |
Features
- MTS™ Buffered Gel Card can be used in ABO Serum Grouping as well as direct agglutination i.e., cold and warm antibody detection
- Delivered with gel-filled microtubes infused with pre-measured reagents
- Gel testing is easy to learn, use, and teach: the ideal technology for all shifts and all levels of blood banking experience
- Eliminates washing, shaking, and the need to add control cells
- Well-balanced sensitivity and specificity means less time and fewer resources spent on clinically unimportant antibodies
- Contains: (100) Buffered Gel Cards each Containing Anti-A (Murine Monoclonal) and Anti-B (Murine Monoclonal)
- The ID-Micro Typing System™ can be easily automated with ID-MTS™ Workstation or Ortho ProVue™ Analyzer
- HIGH Complexity designation – All test systems, assays or examinations used in compatibility testing when performed to determine donor/recipient compatibility: recipient & donor ABO group/D (Rho) type/antigen typing, direct antiglobulin test, tests for unexpected antibody detection & identification, & crossmatch procedures are HIGH Complexity. See: Federal Register notice, February 28, 1992 [57 FR 7245]
- Rx only
Professionals Also Viewed
-
,for, Item ID-
- #1195265
- Providers like you icon 1,259
- Sysmex America #CV377552
- Fluorocell WDF is a staining reagent for use with designated Sysmex Au …
- This reagent is to be handled by laboratory professionals or appropria …
-
,for, Item ID-
- #942801
- Providers like you icon 1,226
- Sysmex America #ZA900001
-
,for, Item ID-
- #1192822
- Providers like you icon 1,008
- Sysmex America #BJ350971
- SLS haemoglobin detection method uses cyanide-free sodium lauryl sulph …
- The reagent lyses red blood cells and white blood cells in the sample
-
,for, Item ID-
- #841033
- Providers like you icon 646
- Sysmex America #BN337547
- The fluorescent dye packs are “printer style%XE2%X80? cartridges that …
- The RFID (Radio Frequency ID) technology optimizes correct placement, …