- #1229849
- Diazyme Laboratories #DZ169A-K
General Chemistry Reagent / Calibrator Kit Human Kappa Free Light Chain CLIA Non-Waived For Clinical Chemistry Analyzers 150 Tests
ASSAY KIT, HUMAN KAPPA FREE LIGHT CHAIN 150-200TESTS
Features
- R1/R2 (Dual Vial Liquid Stable, Immunoturbidimetric) Cal: 5 level (Included with kit)
- The Diazyme Human Kappa (κ) Free Light Chain Assay is intended as a latex particle enhanced immunoturbidimetric assay for the quantitative determination of Kappa Free Light Chain (FLC) concentration in serum on validated analyzers
- The measurement of Kappa FLC in conjunction with Lambda FLC aids in the diagnosis and monitoring of multiple myeloma in conjunction with other laboratory and clinical findings
- More …
Product Details Email
Product Specifications
McKesson # | 1229849 |
---|---|
Manufacturer # | DZ169A-K |
Manufacturer | Diazyme Laboratories |
Country of Origin | United States |
Application | General Chemistry Reagent / Calibrator Kit |
CLIA Classification | CLIA Non-Waived |
CLIA Classified | CLIA Non-Waived |
For Use With | For Clinical Chemistry Analyzers |
Form | Liquid |
Number of Tests | 150 Tests |
Product Dating | McKesson Acceptable Dating: we will ship >= 90 days |
Sample Type | Serum Sample |
Specialty | General Chemistry |
Storage Requirements | Requires Refrigeration |
Test Category | Specific Proteins |
Test Method | Immunoturbidimetric Method |
Test Name | Human Kappa Free Light Chain |
Test Type | Cancer Marker |
Time to Results | 10 Minute Results |
UNSPSC Code | 41116158 |
Volume | R1: 22 mL, R2: 7 mL |
Features
- R1/R2 (Dual Vial Liquid Stable, Immunoturbidimetric) Cal: 5 level (Included with kit)
- The Diazyme Human Kappa (κ) Free Light Chain Assay is intended as a latex particle enhanced immunoturbidimetric assay for the quantitative determination of Kappa Free Light Chain (FLC) concentration in serum on validated analyzers
- The measurement of Kappa FLC in conjunction with Lambda FLC aids in the diagnosis and monitoring of multiple myeloma in conjunction with other laboratory and clinical findings
- Assay utilizes polyclonal antibodies for comprehensive detection
- Aids in the diagnosis and monitoring of multiple myeloma in conjunction with other laboratory finding
Professionals Also Viewed
No Image
-
,for, Item ID-
- #1058698
- Providers like you icon 20
- Abbott #04R2921
- The UIBC assay is used for the quantitative determination of unsaturat …
No Image
-
,for, Item ID-
- #727558
- Providers like you icon 48
- Beckman Coulter #OSR6130
- Measurements of serum lipase are used in the diagnosis and treatment o …
- Lipase activity is stable for several weeks when stored 2 - 8°C or ind …
-
,for, Item ID-
- #1128050
- Providers like you icon 38
- Beckman Coulter #B00389
- The HbA1c (Hemoglobin A1c) reagent, when used in conjunction with Beck …
- The absolute HbA1c and Total Hemoglobin (THb) values generated as part …
- Includes HbA1c Calibrator Levels 1 - 5
No Image
-
,for, Item ID-
- #727602
- Providers like you icon 28
- Beckman Coulter #OSR6230
- Measurements of serum lipase are used in the diagnosis and treatment o …
- Lipase activity is stable for several weeks when stored 2 - 8°C or ind …