Molecular Reagent Starter Pack BioFire® SpotFire® Respiratory Panel CLIA Waived For BioFire SpotFire System 30 Tests
STARTER KIT, SPOTFIRE RESPIRATORY PANEL (30/KT 12/SET) D/S
Features
- Starter Kit, SpotFire, Respiratory Panel (1 Kit reagents, 1 set of pos and neg controls)
- Included controls intended for use as an external assayed quality control to monitor performance of in vitro laboratory nucleic acid testing procedures for the qualitative detection of pathogens on the BIOFIRE® SPOTFIRE Respiratory (R) Panel
- SPOTFIRE® Respiratory Panel is designed to run on the BIOFIRE® SPOTFIRE® System and provides PCR-based results for 15 common viral and bacterial respiratory targets in ~15 minutes
- More …
Product Details Email
Product Specifications
McKesson # | 1241764 |
---|---|
Manufacturer # | 424812 |
Brand | BioFire® SpotFire® |
Manufacturer | Biomerieux Inc (SPOTFIRE) |
Country of Origin | Unknown |
Application | Molecular Reagent Starter Pack |
CLIA Classification | CLIA Waived |
CLIA Classified | CLIA Waived |
Container Type | Individually Wrapped |
For Use With | For BioFire SpotFire System |
Number of Tests | 30 Tests |
Sample Type | Nasopharyngeal Swab Sample |
Specialty | Molecular |
Test Category | Respiratory |
Test Format | Test Device |
Test Name | Respiratory Panel |
Test Type | PCR |
Time to Results | 15 Minute Results |
UNSPSC Code | 41116129 |
Features
- Starter Kit, SpotFire, Respiratory Panel (1 Kit reagents, 1 set of pos and neg controls)
- Included controls intended for use as an external assayed quality control to monitor performance of in vitro laboratory nucleic acid testing procedures for the qualitative detection of pathogens on the BIOFIRE® SPOTFIRE Respiratory (R) Panel
- SPOTFIRE® Respiratory Panel is designed to run on the BIOFIRE® SPOTFIRE® System and provides PCR-based results for 15 common viral and bacterial respiratory targets in ~15 minutes
- The BIOFIRE® SPOTFIRE® Respiratory (R) Panel (SPOTFIRE R Panel) is a multiplexed polymerase chain reaction (PCR) test intended for use with the BIOFIRE® SPOTFIRE® System for the simultaneous, qualitative detection and identification of multiple respiratory viral and bacterial nucleic acids in nasopharyngeal swab (NPS) specimens obtained from individuals with signs and symptoms of respiratory tract infection, including COVID-19
- Sample Type: Nasopharyngeal swab in 1-3 mL of viral transport media
- Hands-on time: 1-2 minutes
- Each kit contains sufficient reagents to test (30) samples: Individually packaged SPOTFIRE R Panel Pouches, Single-use Sample Buffer Ampule, Single-use pre-filled Hydration Injection Vial (blue), Single-use Sample Injection Vial (red), Fixed-volume transfer pipette
- Viruses: Adenovirus, Coronavirus SARS-CoV-2, Coronavirus (seasonal), Human metapneumovirus, Human rhinovirus/enterovirus, Influenza A virus A/H1-2009, Influenza A virus A/H3, Influenza B virus, Parainfluenza virus, Respiratory syncytial virus
- Bacteria: Bordetella parapertussis, Bordetella pertussis, Chlamydia pneumoniae, Mycoplasma pneumoniae
Professionals Also Viewed
No Image
-
,for, Item ID-
- #1016700
- Cepheid #GXCT/NG-SPAK
No Image
-
,for, Item ID-
- #1080514
- Cepheid #XPRSTREPA-SPAK1
- Xpert® Xpress Strep A is a qualitative real-time PCR test providing ac …
- For In Vitro Diagnostic Use
- Careful selection of the target gene produces quality results
-
,for, Item ID-
- #1016702
- Cepheid #GXTV-SPAK1
- The first NAAT to deliver TV results for male urine specimens
- FDA-cleared for both symptomatic and asymptomatic patients
- Delivers positive results in as soon as 40 minutes